Access Control/Wiring of the Reader and Controller: Difference between revisions

From Luminys WIKI
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Header}}
<div class="lm-banner">[[File:LuminysMainPageBanner2.png]]</div>
<div class="lm-banner">[[File:LuminysMainPageBanner2.png]]</div>


Line 10: Line 11:


===Video Instructions===
===Video Instructions===
<!--<embedvideo service="youtube">Coming soon</embedvideo>-->
<youtube>https://youtu.be/CBNlO8BeUV0</youtube>
Coming soon


===Step by Step Instructions===
===Step by Step Instructions===

Latest revision as of 15:14, 18 August 2026

☰ Navigation Menu

Wiring of the Reader and Controller

Description

This tutorial will go over how to wire reader to access control.

Prerequisites

  • Access control and readers

Video Instructions

Step by Step Instructions

1. In the following wiring example, two readers are connected via RS485 to access control.

2. Match the wires of the reader and connect them to the corresponding contacts of the access control.
Purple = 485A
Yellow = 485B
Brown = LED1
Blue = CASE
Black = GND
Red = 12V

Note: For third-party readers, Wiegand connections are supported.